 | Membrane Scrapers- Unique tip design
- Optimal flex for ILM purchase
- Compact shelf-friendly packaging*
Download Brochure |
*GreenTip Membrane Scraper
GreenTip Soft Tip Cannula Effectively visualize and assess the proximity of the retina with the “fluorescing” GreenTip cannula. Unlike transparent silicone-tipped needles, the GreenTip is designed to provide optimal contrast against the red-orange background of the retina. Gain More Control with Better Visualization - Patented green tip design maximizes visualization against retina
- Atraumatic silicone tip protects the retina during aspiration and subretinal fluid drainage
- Standard tip design maximizes flow
- Brush tip design protects the tissue by directing partial flow along the side of the tip
- New 0.5 mm standard tip allows for easy insertion and improved fit in valved cannulas* Click for datasheet
- Available in 0.5mm, 1.0mm and 2.5mm lengths
*U.S. Patents: 6,800,076; 7,537,593; 8,177,777 This text will be replaced | | GreenTip™ Soft Tip cannulas Enhanced visualization with the 'Fluorescing' GreenTip cannula. |
Illuminated ProductsLight Probes (Box of 5) Light Probe Light Pick (Straight) | - -
| PD100.23 PD123.03A
| - -
| Accessories Alcon/Grieshaber Light Source Adapter B&L Light Source Adapter | PD125.05 PD125.15 | Illuminated Bipolar Cautery (Box of 5) Straight | PD100.03 | PD123.13 | - |
MoistAir™ In-Line Air Humidifier Enhanced surgical performance by reducing dehydrating effects of dry air in the posterior chamber with the MoistAir humidifier.1,2 Peer-reviewed studies show: - Delayed crystalline lens feathering3
- May prevent visual of field defects after macular hole surgery3,4
- Protection of the corneal endothelium6,7
The MoistAir chamber inserts into any standard tubing and is self-priming when placed between the stop cock and infusion cannula. - Harlan JB, Jr., Lee ET, Jensen PS, de Juan E, Jr. Effect of humidity on posterior lens opacification during fluid-air exchange. Arch Ophthalmol 1999;117(6):802-4.
- Welch JC. Dehydration injury as a possible cause of visual field defect after pars plana vitrectomy for macular hole. Am J Ophthalmol 1997;124(5):698-9.
- Ohji M, Nao IN, Saito Y, Hayashi A, Tano Y. Prevention of visual field defect after macular hole surgery by passing air used for fluid-air exchange through water. Am J Ophthalmol 1999;127(1):62-6.
- Cekic O, Ohji M, Zheng Y, Hayashi A, Kusaka S, Tano Y. Experimental study of viscoelastic in the prevention of corneal endothelial desiccation injury from vitreal fluid- air exchange. Am J Ophthalmol 2003;135(5):641-7.
- Cekic O, Ohji M, Hayashi A, Fang XY, Kusaka S, Tano Y. Effects of humidified and dry air on corneal endothelial cells during vitreal fluid-air exchange. Am J Ophthalmol 2002;134(1):75-80.
- Cekic O, Ohji M, Hayashi A, Fang XY, Kusaka S, Tano Y. Humidified air effect on pupil size during fluid-air exchange. Retina 2001;21(5):529-31.
- Eter N, Brinken R, Garbe S, Spitznas M. Intraocular humidity immediately after fluid-air exchange in pars plana vitrectomy. Graefes Arch Clin Exp Ophthalmol 2006;244(3):305-8
This text will be replaced | | MoistAir™ Humidifier Chamber Reduces the effects of dry air in the posterior chamber. |
Endoview™ Sapphire Surgical Contact Lenses* Manufactured from a single-crystal sapphire, the Endoview Sapphire lenses offer clarity and superior visualization over standard quartz lenses. Durability with Superior Performance - Scratch and chip proof
- High refractive index for a wide field viewing
- Increased visualization during fluid-gas exchange
- Reusable
- Wide array of lens models available
20 Gauge - Regular Flex Retractable Tip 20 Gauge - Regular Flex Standard Tip 20 Gauge - Super Flex Standard Tip | | PD800.00 PD800.20 PD800.20SF | 23 Gauge - GreenTip™ 23 Gauge - Regular Flex Standard Tip 23 Gauge - Super Flex Standard Tip | | 15940 PD800.23 PD800.23SF | 25 Gauge - GreenTip 25 Gauge - Regular Flex Standard Tip 25 Gauge - Super Flex Standard Tip | | 15950 PD800.25 PD800.25SF | 23 Gauge - Standard Tip 0.5mm | | 15860 | 25 Gauge - Standard Tip 0.5mm | | 15870 | Download Now 20 Gauge - Illuminated Bipolar Cautery Straight | | PD100.03 | 23 Gauge - Light Probe 23 Gauge - Light Pick (Straight) 23 Gauge - Illuminated Bipolar Cautery Straight | | PD100.23 PD123.03A PD123.13 | Alcon/Grieshaber Light Source Adapter B&L Light Source Adapter | | PD125.05 PD125.15 | MoistAir Humidifying Chamber | | 200-10 |
|
|
|