|
|
|
|
Veterinary Products
Successfully treating animal eye disorders such as cataracts, glaucoma, and retinal diseases. With exclusive MicroPulse® technology and continuous wave, the Cyclo G6® Glaucoma Laser allows non-incisional, non-destructive, and repeatable treatment for a wide range of glaucoma cases. The DioVet™ System, with a 810nm wavelength, is ideal for penetrating nonpigmented ocular tissues including sclera, cornea, and aqueous/vitreous, used in combination with a line of delivery devices. It enables transscleral glaucoma and retinal procedures with greater accuracy and less postoperative pain than cryotherapy.
"At Veterinary Vision we frequently use the diode laser from Iridex for treating a variety of conditions including uveal, limbal and eyelid melanomas, and iris cysts. There are many delivery systems available, including the operating microscope adapter (OMA), retinopexy, EndoProbe and transscleral probes, allowing the laser to be delivered in both contact and non contact modes. Diode laser treatment for glaucoma includes transscleral and endo cyclophotocoagulation techniques offering some of the best options available for treating this challenging condition."
"Recent availability of the Cyclo G6 Glaucoma Laser System offers another modality for reducing aqueous production as a treatment for glaucoma. MicroPulse technology has the potential to achieve optimal cyclodestructive effects with much less inflammation and potential for damaging postoperative intraocular pressure spikes. We are fortunate to be among the veterinary centers beginning to accumulate data using this novel technology."
Cynthia Cook, DVM, PhD, Diplomate ACVO, San Carlos and San Francisco, Veterinary Vision, Inc
|
Schedule a hands-on demo
Schedule a no-obligation demo to see for yourself how MicroPulse Technology and Iridex’s Family of Products can take YOUR practice to the next level.
Upcoming Events
ACVO
October 15 - 18, 2025.
Grapevine, TX.
Gaylord Marriott Texan
|
Cyclo G6® Glaucoma Laser System
With exclusive MicroPulse technology and continuous wave, the Cyclo G6 Glaucoma Laser allows treatment for a wide range of glaucoma cases. With the MicroPulse P3® Probe, it enables a versatile procedure with multiple safety benefits, including: non-incisional, non-destructive, repeatable, and predictable treatment. MicroPulse technology delivers repetitive, low-energy laser ‘micropulses’ which reduce risks associated with other destructive therapies. MicroPulse is a noninvasive therapy that does not require any incisions or implants. The procedure does not cause tissue damage, therefore the doctor may repeat it as needed for glaucoma management.
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
DioVet™ 810nm Laser
The DioVet laser system is used worldwide by veterinary ophthalmologists to treat glaucoma, retinal disorders, and pigmented tumors. The 810 nm laser wavelength enables transscleral cyclophotocoagulation for glaucoma and retinal procedures. The small size of the DioVet laser system allows easy transport of the equipment to multiple clinics or remote.
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
Veterinary Delivery Devices
The Iridex LIO Plus is an easy-to-use single-mirror laser indirect ophthalmoscope that is ergonomic and provides excellent peripheral visualization, treatment flexibility, consistency, and reliability. For many years, it has been considered the gold standard of LIOs and has been widely used by retina specialists and teaching institutions around the world.
- TruFocus optical system for great working distance and diagnostic capabilities
- Independent positioning of the laser within illumination field for efficient peripheral treatments
- LED illumination offers virtually unlimited working life (up to 20,000 hours)
Learn more
Transscleral 600 micron - Glaucoma Probe
- Photocoagulation of ciliary processes reduces IOP
- Consistent scleral depression via fiber-tip protrusion
- Unique probe tip design allows accurate, consistent placement of laser burn on animal eyes
- Up to 2.0 Watts of power delivered to target tissue
Learn more
EndoProbe devices can be used for endophotocoagulation procedures to treat the same types of retinal conditions seen in humans.
Learn more
The operating microscope adapter (OMA) is effective in the treatment of pigmented iris melanomas, limbal melanomas, eyelid melanomas, and iris cysts, providing precise control, great visualization, and a variety of spot sizes.
Learn more
A cost-effective combination of safety, efficacy, durability, and repeatability in a non-incisional approach to glaucoma care. MicroPulse Transscleral Laser Therapy via the MicroPulse P3® Device offers you and your patients a therapy that can be introduced prior to, in conjunction with, and following all other available glaucoma treatment options. It allows treatment at several different time points throughout the course of the disease.
Learn more
The G-Probe® Delivery Device performs Continuous-Wave Transscleral Cyclophotocoagulation (CW-TSCPC) to lower IOP through selective ablation of the ciliary processes. This simple yet effective, repeatable procedure can be performed in the office, operating room, or in conjunction with other procedures, such as cataract surgery.
Learn more
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
Cyclo G6® Glaucoma Laser System |
|
CYCLO G6 GLAUCOMA LASER SYSTEM |
MicroPulse® P3 Glaucoma Device |
|
15522 |
G-Probe® |
|
15980 |
DioVet™ 810 nm |
|
VET SYSTEM |
LIO with Heine Headband 500 model |
|
13152-H500 |
Glaucoma Transscleral 600 micron probe |
|
11568 |
EndoProbe® (Click here to see EndoProbe models)
|
|
|
|
|
|
Zeiss OPMI-6 |
|
11672 |
Zeiss OPMI-MDO/OPMI-MDU |
|
11673 |
Zeiss OPMI-I/OPMI-19 |
|
11688 |
Zeiss OPMI CS w/ Retrolux |
|
11890 |
Zeiss OPMI CS w/ Weck |
|
11818 |
Zeiss VISU 150/200 |
|
13411 |
Leica OMA M841/M844 |
|
14308 |
Leica M650/M690/M840/M841 |
|
11671 |
* Appropriate eye safety filter required
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
This page is currently being updated. In the meantime, for any information you are looking for, please contact info@iridex.com
|
|
|
|
|
|